Search results for "Endodontic files"

showing 7 items of 7 documents

Transportation Assessment in Simulated Curved Canals after preparation with Twisted File Adaptive and BT-Race instruments.

2017

BACKGROUND This study compared the incidence of deviation along curved canals after preparation with two nickel-titanium (NiTi) rotary systems, Twisted File Adaptive and BT-RaCe. MATERIAL AND METHODS Forty resin training blocks with curved canals were filled with ink and divided into two groups according to the instrumentation technique. Preinstrumentation images were acquired by using a stereomicroscope. The canals were up to an instrument #35/0.04. Postinstrumentation images were captured using the same conditions, and the images were superimposed. The amount of resin removed was measured at 8 different points, beginning at the apical terminus of the canal. Differences in the mesial and d…

0301 basic medicineOrthodonticsbusiness.industryInstrumentationResearch030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Operative Dentistry and Endodontics03 medical and health sciences030104 developmental biology0302 clinical medicineUNESCO::CIENCIAS MÉDICASStereo microscopeEndodontic filesbusinessGeneral DentistryComputer hardwareMathematicsJournal of clinical and experimental dentistry
researchProduct

The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device

2021

The aim of this study was to analyze the effect of the taper and apical diameter of nickel&ndash

Characteristic strengthinorganic chemicalsCyclic stressmedicine.medical_specialtyMaterials scienceapical diameterlcsh:TechnologyDynamic resistancelcsh:Chemistry03 medical and health sciences0302 clinical medicine0502 economics and businessEndodontic filesmedicineotorhinolaryngologic diseasesGeneral Materials SciencetaperInstrumentationlcsh:QH301-705.5endodontic rotary filesWeibull distributionFluid Flow and Transfer ProcessesOrthodonticsWeibull moduluslcsh:TProcess Chemistry and Technology05 social sciencesGeneral Engineering030206 dentistryEndodonticscyclic fatiguelcsh:QC1-999Computer Science Applicationsendodonticslcsh:Biology (General)lcsh:QD1-999Nickel titaniumlcsh:TA1-2040050211 marketingrotary movementlcsh:Engineering (General). Civil engineering (General)lcsh:PhysicsApplied Sciences
researchProduct

Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model

2021

Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodont…

Cyclic stressStudy groupsCyclic fatigueEndodontics03 medical and health sciencesReciprocating motion0302 clinical medicineGermanyMaterials Testing0502 economics and businessEndodontic filesHumansMedicineGeneral DentistryTitaniumOrthodonticsbusiness.industry05 social sciencesEquipment Design030206 dentistryNitinollcsh:RK1-715lcsh:DentistryReflexEquipment Failure050211 marketingReciprocating movementbusinessRoot Canal PreparationResearch ArticleBMC Oral Health
researchProduct

Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study

2011

The aim of this study is to evaluate if theoretically possible edge shifts induced by noise-suppression filters potentially occur on objects found in digital radiographs. Most manufacturers carry out noise-suppression filtering of their images before they are displayed to the user. It is not usually possible for the user to disrupt the function of the filters. The use of these filters can lead to deletion of small image structures.K-files (ISO size 06, 08, 10 and 15) were placed in the root canals of 6 human teeth located in cadaver jaw segments. File tip positions were measured on original and filtered digital images by three observers. The file position was marked on each filtered image a…

Dental InstrumentsRadiographyDentistryMandibleStandard deviationDigital imageCadaverEndodontic filesCadaverHumansRadiology Nuclear Medicine and imagingComputer visionGeneral DentistryMathematicsNoise suppressionPixelbusiness.industryResearchGeneral MedicineEquipment DesignRadiography Dental DigitalImage enhancementOtorhinolaryngologySubtraction TechniqueArtificial intelligenceDental Pulp CavitybusinessArtifactsFiltrationRoot Canal Preparation
researchProduct

Evaluation of a digital radiography to estimate working length

1997

The working lengths obtained with different methods in single-rooted teeth were compared. An endodontic rule in millimeters and calipers was used as a direct method of measurement (on endodontic files). As indirect methods, measurements were taken from conventional x-rays with calipers and with a digital radiological measurement system. No statistically significant differences were obtained between the direct and indirect methods. Three vertical angulations were taken for the indirect methods (0 degree, 15 degrees, and 30 degrees). No significant differences were found between results for the two indirect methods versus the standard method except for the 30 degrees angulation, which resulte…

Observer Variationbusiness.industryDirect methodDentistryRadiography Dental DigitalStatistics NonparametricRoot Canal TherapyIncisorStatistical significanceEndodontic filesOdontometryMedicineCalipersDental Pulp CavityTooth RootbusinessGeneral DentistryDigital radiographyJournal of Endodontics
researchProduct

Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study

2021

The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Materials and Methods: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10)

Orthodonticsmedicine.medical_specialtyCyclic stressbusiness.industryRoot canalRGeneral Medicinecyclic fatigueEndodonticsenergy-dispersive X-rayArticleNiTiNiti alloyendodonticscross-section designCross section (physics)medicine.anatomical_structureNickel titaniummedicineEndodontic filesMedicineIn vitro studybusinesscontinuous rotationJournal of Clinical Medicine
researchProduct

The influence of NiTi alloy on the cyclic fatigue resistance of endodontic files

2020

Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41)

medicine.medical_specialtyCyclic stressEndodontics.Titanium in Dentistry.Titanio - Aplicaciones en Odontología.Endodoncia.NiTi alloylcsh:Medicine02 engineering and technologyDental metallurgy.ArticleDientes - Cavidades - Preparación.Niti alloy03 medical and health sciencesTeeth - Roots - Planing.0302 clinical medicineCM-Blue WiremedicineEndodontic filesNickel in Dentistry.Statistical analysisDental therapeutics - Equipment and supplies.OrthodonticsTerapéutica dental - Aparatos y material.business.industrylcsh:RAleaciones en odontología.Direct observationAnova test030206 dentistryGeneral Medicine021001 nanoscience & nanotechnologyEndodonticscyclic fatigueNíquel - Aplicaciones en Odontología.endodonticsM-WireNickel titaniumCM-Gold Wire0210 nano-technologybusiness
researchProduct