Transportation Assessment in Simulated Curved Canals after preparation with Twisted File Adaptive and BT-Race instruments.
2017
BACKGROUND This study compared the incidence of deviation along curved canals after preparation with two nickel-titanium (NiTi) rotary systems, Twisted File Adaptive and BT-RaCe. MATERIAL AND METHODS Forty resin training blocks with curved canals were filled with ink and divided into two groups according to the instrumentation technique. Preinstrumentation images were acquired by using a stereomicroscope. The canals were up to an instrument #35/0.04. Postinstrumentation images were captured using the same conditions, and the images were superimposed. The amount of resin removed was measured at 8 different points, beginning at the apical terminus of the canal. Differences in the mesial and d…
The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
2021
The aim of this study was to analyze the effect of the taper and apical diameter of nickel&ndash
Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model
2021
Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodont…
Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study
2011
The aim of this study is to evaluate if theoretically possible edge shifts induced by noise-suppression filters potentially occur on objects found in digital radiographs. Most manufacturers carry out noise-suppression filtering of their images before they are displayed to the user. It is not usually possible for the user to disrupt the function of the filters. The use of these filters can lead to deletion of small image structures.K-files (ISO size 06, 08, 10 and 15) were placed in the root canals of 6 human teeth located in cadaver jaw segments. File tip positions were measured on original and filtered digital images by three observers. The file position was marked on each filtered image a…
Evaluation of a digital radiography to estimate working length
1997
The working lengths obtained with different methods in single-rooted teeth were compared. An endodontic rule in millimeters and calipers was used as a direct method of measurement (on endodontic files). As indirect methods, measurements were taken from conventional x-rays with calipers and with a digital radiological measurement system. No statistically significant differences were obtained between the direct and indirect methods. Three vertical angulations were taken for the indirect methods (0 degree, 15 degrees, and 30 degrees). No significant differences were found between results for the two indirect methods versus the standard method except for the 30 degrees angulation, which resulte…
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
2021
The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Materials and Methods: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10)
The influence of NiTi alloy on the cyclic fatigue resistance of endodontic files
2020
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41)